What Is the ACTH Stimulation Test? What It Measures
The ACTH stimulation test is a laboratory procedure in which a synthetic adrenocorticotropic hormone analogue, generically called cosyntropin or tetracosactide, is given and blood cortisol is measured before and after. Published work describes it as a way to evaluate suspected adrenal insufficiency by seeing whether the adrenal cortex raises cortisol after stimulation. Cutoffs differ by assay, laboratory and protocol, and reviews describe several interpretive pitfalls. A result is one data point that a clinician interprets alongside history, timing and other tests.
The ACTH stimulation test, also written as the ACTH stim test or cosyntropin stimulation test, is a laboratory procedure that examines how the adrenal cortex responds when it is deliberately stimulated. A synthetic analogue of adrenocorticotropic hormone, named generically as cosyntropin (called tetracosactide in some countries), is administered, and blood cortisol is measured before and after. The test is a measurement tool, not a treatment, and its output is a set of cortisol values that a clinician interprets in context.
This page is for educational purposes only and is not medical advice; consult a licensed physician about any question concerning testing, symptoms or hormone evaluation. Nothing here describes how a test should be performed on any individual.
What the ACTH Stimulation Test Measures
Adrenocorticotropic hormone is the pituitary signal that drives cortisol production by the adrenal cortex. The stimulation test substitutes a short synthetic fragment of that hormone for the body's own signal, then asks a single measurable question: does circulating cortisol rise after the adrenal glands receive a strong stimulus?
The measured variable is serum or plasma cortisol, usually sampled at baseline and again at fixed intervals after the analogue is given. Some research protocols also measure steroid precursors in the same samples. A 2022 report on 3beta-hydroxysteroid dehydrogenase 2 deficiency described how stimulated steroid profiles, not cortisol alone, were used to characterise a heterogeneous spectrum of adrenal steroidogenesis disorders (https://pubmed.ncbi.nlm.nih.gov/36140569/).
How the Test Is Performed in General Terms
In broad outline, and as described across the diagnostic literature, the procedure involves a baseline blood draw for cortisol, administration of the synthetic ACTH analogue by injection, and one or more timed blood draws afterward. Protocols differ in the amount of analogue used, the route of administration, and the sampling times. A 2019 study in children used a long acting intramuscular ACTH preparation rather than the short acting form, and researchers assessed its performance for secondary adrenal insufficiency (https://pubmed.ncbi.nlm.nih.gov/30530907/).
Because protocol details vary between centres, the numbers produced by one laboratory are not automatically comparable to another. This page does not list amounts, timings or step by step instructions, and no reader should infer a procedure from it.
Doing the math on a vial? The PeptideU app does reconstitution, units and dilution for you.
Try it freeWhat the Test Is Used to Evaluate
The published indication for the test is the evaluation of suspected adrenal insufficiency, meaning inadequate cortisol production. The literature divides this into primary adrenal insufficiency, where the adrenal glands themselves are the problem, and secondary adrenal insufficiency, where the pituitary fails to produce enough ACTH. A review of secondary hypoadrenalism described the clinical features, causes and diagnostic approach to pituitary driven cortisol deficiency (https://pubmed.ncbi.nlm.nih.gov/18418713/). A separate review of isolated corticotrophin deficiency described a form in which ACTH production is deficient while other pituitary hormones remain intact (https://pubmed.ncbi.nlm.nih.gov/17077949/).
The distinction matters for interpretation. In long standing secondary adrenal insufficiency, the adrenal cortex can become understimulated over time, which is the physiological reason the stimulation test is also applied to pituitary disorders rather than adrenal disorders alone, as discussed in the secondary hypoadrenalism review (https://pubmed.ncbi.nlm.nih.gov/18418713/).
How Published Studies Report That Results Are Read
Interpretation rests on the stimulated cortisol value, and the threshold used to separate an adequate from an inadequate response is not a fixed universal number. A 2022 study derived new diagnostic cutoffs for adrenal insufficiency after cosyntropin stimulation using a modern automated cortisol immunoassay, and the researchers reported that thresholds appropriate for older assays did not transfer directly to the newer platform (https://pubmed.ncbi.nlm.nih.gov/35487459/). That finding is the clearest reason this page gives no numeric reference ranges: a cutoff is a property of a specific assay, laboratory and protocol, not of the test in the abstract.
A 2019 review catalogued pitfalls in interpreting the cosyntropin stimulation test for adrenal insufficiency, including analytical differences between cortisol assays and clinical situations that alter cortisol binding proteins and therefore total cortisol measurements (https://pubmed.ncbi.nlm.nih.gov/30855285/). A 2019 reassessment of the low dose test likewise concluded that the cutoff value used for diagnosis required re-examination rather than being treated as settled (https://pubmed.ncbi.nlm.nih.gov/31195750/).
Taken together, these sources describe interpretation as assay dependent, protocol dependent and clinician led, not as a simple pass or fail reading from a single printed number (https://pubmed.ncbi.nlm.nih.gov/30855285/, https://pubmed.ncbi.nlm.nih.gov/35487459/).
Tracking research? Log entries with dates, lots and notes: records, never plans.
Get the appLow Dose Versus Standard Dose Protocols in the Literature
Research has compared a low dose version of the test against the standard dose version, and the comparison has produced mixed conclusions. A 2002 study concluded that the low dose ACTH test did not provide a useful assessment of the hypothalamic pituitary adrenal axis in secondary adrenal insufficiency (https://pubmed.ncbi.nlm.nih.gov/11966747/). A 2012 study compared low dose and high dose cosyntropin stimulation tests for diagnosing adrenal insufficiency in patients with septic shock, a setting where cortisol physiology and binding proteins are disturbed (https://pubmed.ncbi.nlm.nih.gov/22351474/).
A 2019 analysis revisited the accuracy of the low dose test and focused specifically on where the diagnostic cutoff should sit, reinforcing that the same protocol can yield different classifications depending on the threshold applied (https://pubmed.ncbi.nlm.nih.gov/31195750/). No amounts are reproduced on this page, because protocol amounts belong to study design and to clinicians, not to general readers.
Settings Studied Beyond Routine Outpatient Evaluation
Published work has applied the test in several specific populations. A 2013 study examined traumatic brain injury and adrenal insufficiency using morning cortisol and cosyntropin stimulation tests, and the researchers compared what each measurement contributed in that population (https://pubmed.ncbi.nlm.nih.gov/23515961/). In critical illness, the 2012 septic shock comparison addressed whether the stimulation test could distinguish adrenal insufficiency when baseline cortisol is already elevated by acute stress (https://pubmed.ncbi.nlm.nih.gov/22351474/).
In paediatrics, a 2023 study compared the glucagon stimulation test with the low dose ACTH test for assessing the hypothalamic pituitary adrenal axis in children (https://pubmed.ncbi.nlm.nih.gov/36750758/), and a 2019 study evaluated a long acting intramuscular ACTH stimulation test for diagnosing secondary adrenal insufficiency in children (https://pubmed.ncbi.nlm.nih.gov/30530907/). These papers illustrate that the test exists in several variants, each studied separately.
Want the full course? Every compound, evidence-graded and cited, inside PeptideU.
Start learning freeHow It Differs From a Basal ACTH Blood Test
A basal ACTH blood test measures the concentration of the body's own adrenocorticotropic hormone in a single blood sample, without giving any stimulating agent. The stimulation test does the opposite: it supplies an external ACTH analogue and measures the adrenal response in cortisol. The two tests answer different questions and are often considered together.
| Feature | ACTH stimulation test | Basal ACTH blood test |
|---|---|---|
| Agent given | Synthetic ACTH analogue (cosyntropin or tetracosactide) | None |
| Primary analyte measured | Cortisol, before and after stimulation | Endogenous ACTH concentration |
| Question addressed | Can the adrenal cortex raise cortisol when stimulated | How much ACTH the pituitary is producing at that moment |
| Sampling | Baseline plus timed post stimulation samples | Usually a single timed sample |
| Interpretation | Compared with an assay specific and protocol specific threshold | Compared with a laboratory reference interval and read alongside cortisol |
In the secondary hypoadrenalism literature, endogenous ACTH level is one of the features used to separate pituitary driven from adrenal driven cortisol deficiency, while the stimulation test assesses the adrenal response itself (https://pubmed.ncbi.nlm.nih.gov/18418713/). The review of isolated corticotrophin deficiency likewise describes a pattern in which ACTH signalling is the deficient element (https://pubmed.ncbi.nlm.nih.gov/17077949/).
What a Result Can and Cannot Show
What a result can contribute, according to the cited literature, is evidence about whether the adrenal cortex produced an adequate cortisol rise under a defined protocol and assay (https://pubmed.ncbi.nlm.nih.gov/35487459/). What it cannot do, per the 2019 pitfalls review, is deliver an assay independent verdict, because binding protein changes and analytical differences can shift measured total cortisol without a change in adrenal capacity (https://pubmed.ncbi.nlm.nih.gov/30855285/).
- Not a standalone diagnosis. The 2013 traumatic brain injury study paired morning cortisol with cosyntropin stimulation rather than relying on either alone (https://pubmed.ncbi.nlm.nih.gov/23515961/).
- Not interchangeable across protocols. Low dose and standard dose versions have been compared and did not perform identically in the studied settings (https://pubmed.ncbi.nlm.nih.gov/11966747/, https://pubmed.ncbi.nlm.nih.gov/22351474/).
- Not the only axis test. A 2025 study assessed the performance of dehydroepiandrosterone sulfate and baseline cortisol in evaluating adrenal insufficiency, examining whether simpler measurements could triage who needs stimulation testing (https://pubmed.ncbi.nlm.nih.gov/39657727/), and the 2023 paediatric comparison placed the glucagon stimulation test alongside the low dose ACTH test (https://pubmed.ncbi.nlm.nih.gov/36750758/).
- Not a measure of pituitary output. That question belongs to the basal ACTH measurement, as described in the secondary hypoadrenalism review (https://pubmed.ncbi.nlm.nih.gov/18418713/).
Adverse Events: What Studies Report
The verified sources summarised on this page were designed to examine diagnostic accuracy, cutoff derivation and protocol comparison rather than tolerability, so they do not supply adverse event rates. The 2019 review addressed interpretive pitfalls of the cosyntropin stimulation test rather than safety outcomes (https://pubmed.ncbi.nlm.nih.gov/30855285/), and the 2022 cutoff study reported analytical and diagnostic performance using a modern cortisol immunoassay (https://pubmed.ncbi.nlm.nih.gov/35487459/). Questions about safety for any individual belong to a licensed physician who knows that person's history.
Related Reading on PeptideU
References
- Pitfalls in the interpretation of the cosyntropin stimulation test for the diagnosis of adrenal insufficiency (Current Opinion in Endocrinology, Diabetes, and Obesity, 2019)
- New Diagnostic Cutoffs for Adrenal Insufficiency After Cosyntropin Stimulation Using Abbott Architect Cortisol Immunoassay (Endocrine Practice, 2022)
- Traumatic brain injury and adrenal insufficiency: morning cortisol and cosyntropin stimulation tests (Archives of Medical Science, 2013)
- Comparison of glucagon stimulation test and low dose ACTH test in assessing hypothalamic-pituitary-adrenal (HPA) axis in children (Clinical Endocrinology, 2023)
- Secondary hypoadrenalism (Pituitary, 2008)
- Long-acting intramuscular ACTH stimulation test for the diagnosis of secondary adrenal insufficiency in children (Journal of Pediatric Endocrinology and Metabolism, 2019)
- Isolated corticotrophin deficiency (Pituitary, 2006)
- Accuracy of the Low-Dose ACTH Stimulation Test for Adrenal Insufficiency Diagnosis: A Re-Assessment of the Cut-Off Value (Journal of Clinical Medicine, 2019)
- Comparison of low and high dose cosyntropin stimulation tests in the diagnosis of adrenal insufficiency in septic shock patients (Hormone and Metabolic Research, 2012)
- The low-dose ACTH test does not provide a useful assessment of the hypothalamic-pituitary-adrenal axis in secondary adrenal insufficiency (Clinical Endocrinology, 2002)
- Approach of Heterogeneous Spectrum Involving 3beta-Hydroxysteroid Dehydrogenase 2 Deficiency (Diagnostics, 2022)
- Performance of Dehydroepiandrosterone Sulfate and Baseline Cortisol in Assessing Adrenal Insufficiency (Journal of Clinical Endocrinology and Metabolism, 2025)
Frequently asked questions
What does the ACTH stimulation test actually measure?▾
It measures blood cortisol before and after a synthetic ACTH analogue is administered, so the analyte is cortisol rather than ACTH itself. Published work frames the result as evidence about whether the adrenal cortex can raise cortisol when stimulated, interpreted against an assay specific threshold (PMID 35487459). A 2019 review described interpretive pitfalls that affect that reading (PMID 30855285).
How is the ACTH stimulation test different from a basal ACTH blood test?▾
A basal ACTH blood test measures the body's own adrenocorticotropic hormone in a single sample with nothing administered. The stimulation test supplies an external ACTH analogue and tracks the cortisol response. Reviews of secondary hypoadrenalism describe endogenous ACTH level as one feature separating pituitary driven from adrenal driven cortisol deficiency (PMID 18418713), while isolated corticotrophin deficiency reflects deficient ACTH signalling (PMID 17077949).
Why are no reference ranges or cutoffs listed on this page?▾
Because thresholds are properties of a particular assay, laboratory and protocol rather than of the test in general. Researchers derived new diagnostic cutoffs for a modern automated cortisol immunoassay and reported that older thresholds did not transfer directly (PMID 35487459). A separate analysis re-assessed the cutoff used for the low dose version (PMID 31195750). A clinician applies the correct local threshold.
What condition is the test used to evaluate?▾
The published indication is suspected adrenal insufficiency, covering both adrenal causes and pituitary causes of inadequate cortisol production. A review of secondary hypoadrenalism described the causes and diagnostic approach to pituitary driven cortisol deficiency (PMID 18418713), and a review of isolated corticotrophin deficiency described a form in which ACTH production alone is deficient (PMID 17077949).
Do low dose and standard dose versions give the same answer?▾
Not necessarily. One study concluded the low dose ACTH test did not provide a useful assessment of the hypothalamic pituitary adrenal axis in secondary adrenal insufficiency (PMID 11966747), and another compared low and high dose cosyntropin tests in septic shock patients, where cortisol physiology is disturbed (PMID 22351474). A later analysis re-examined the low dose cutoff value itself (PMID 31195750).
Are there alternatives or companion tests in the literature?▾
Yes. A 2025 study assessed how dehydroepiandrosterone sulfate and baseline cortisol performed in evaluating adrenal insufficiency (PMID 39657727), and a 2023 paediatric study compared the glucagon stimulation test with the low dose ACTH test (PMID 36750758). A 2013 study paired morning cortisol with cosyntropin stimulation in traumatic brain injury (PMID 23515961).
Can one stimulation result settle a diagnosis by itself?▾
The cited literature does not present it that way. A 2019 review listed pitfalls including assay differences and altered cortisol binding proteins that can shift measured total cortisol (PMID 30855285), and studies have examined the test alongside other measurements rather than alone (PMID 23515961). Interpretation is performed by a licensed clinician using the full clinical picture.
Track it. Calculate it. Actually understand it.
References
This page summarises published research for education. It is not medical advice, and nothing here is a recommendation to use, purchase, or dose any substance. Study parameters described are what researchers reported, not instructions. Consult a qualified clinician before any health decision.